Perfluorinated Sulfonic Acid Ion-Exchange Membrane SY15P Reinforced by PTFE,the SY15P membranes are supplied in pre-expanded wet form. They provide an easy-to-use membrane while offering improved resistance to membrane damage from handling.
Operating Instructions
1, the voltage: <2.8—3.0v
2, the current density: 3.0—6.0 kA/m2
3, or based on the operation condition
Technical Specifications(Reference Standard):
Physical Properties |
Values |
Pinholes >50um |
0 |
Folding Resistance – Horizontal (times) |
>40 |
Folding Resistance –Vertical (times) |
>30 |
Breaking Strength - Horizontal (N) |
>45 |
Breaking Strength - Vertical (N) |
>45 |
Tear Resistance – Horizontal (N) |
>25 |
Tear Resistance –Vertical (N) |
>20 |
Bursting Strength (MPa) |
>0.8 |
Surface Resistance (Ω·cm2) |
<3.2 |
Peel Strength (MPa) |
50.0±5.0 |
Thickness and Weight:
Applications:
The Ion-Exchange Membrane SY-15P is mainly used in chlor-alkali electrolyzerChlor-alkali membrane is produced with sacrificial core material, suitable for 30-32% caustic soda production.
Chlor-alkali membrane is suitable for running bars with high current density.
Chlor-alkali membrane has higher tolerance to salt water impurities
Packing:
standard size: 1480*2460 mmThe membrane pieces or rolls can be cut to non-standard sizes, please contact our sales staff for details and availability.
Electrodialysis Device for Lab Testing
Graphene Perfluorinated IEM SY-11GP
Perfluorinated IEM for Flow Battery
Ion Exchange Membrane for Fuel Cell
Perfluorinated IEM for Water Treatment
PTFE Enhanced Perfluorinated IEM
Perfluorinated IEM for Electrolysis
Hydrogen-rich Water Cup Membrane